Issue | Probable Cause | Solution |
|
"LoBAtt" | Batteries below 7 vdc | |
Beeps and display flashes | Limit value enabled | - Press the Total key. Press the PLUS key. Press the CLEAR key. Press ENTER to return to the weigh mode.
- Battery Models - Press the TOTAL key twice. Enter "0" from the numeric keypad and press ENTER. Press TOTAL to return to the weigh mode.
|
Does not return to ZERO. Does not repeat known weight. | Bind | - Check for debris under platform.
- Check for objects leaning against the platform.
|
Does not return to ZERO. Does not repeat known weight. | Defective load cell | |
Incorrect count | Sample size too small. | - Resample the product using a larger quantity of pieces.
|
Incorrect count | Pieces weighed are not uniform | - Resample the product using a larger quantity of pieces.
|
No display | No power | - Check to ensure power cord is plugged into the outlet.
- Check circuit breaker.
|